Linear heat detection cable allows pre action or deluge type fire sprinkler system to be more efficient by quickly recognizing the fire and conveying the information back to the fire alarm panel.
Linear heat detection cable installation.
Class b type installation class a type installation has returnable feed and can also be configured a guidewire can be attached to the lhd cable.
Applications can range from building fire alarm systems to mobile plant machinery.
Spot heat detectors 302 series rate anticipation.
Linear heat detection lhd cable is essentially a two core cable terminated by an end of line resistor resistance varies with application.
The linear heat detection cable lhdc system from hochiki is designed to provide early detection of fire and overheating in circumstances where other forms of detection would not be viable either due to inability to sustain the environmental requirements or through prohibitive costs.
Spot heat detectors 5600 series.
68ºc 78ºc 88ºc and 105ºc.
My company united fire protection corp.
This makes lhd linear heat sensor cable to be the most adequate fire detection system for extreme environmental conditions.
Throughout this time i have always found protectowire products to be best in class.
Linear heat detection lhd also known as linear detection wire or linear heat detection cable or linear heat is a very commonly used method of fire detection it can detect a fire anywhere along the length of the cable and can be of lengths in excess of a kilometer.
Junction boxes and feed cable.
Safe fire detection 5915 stockbridge dr monroe nc 28110 704 821 7920.
The global leading manufacturer of linear heat detection systems.
Linear heat cable versatile economical heat detection.
1 1 temperature ranges and outer extrusion types there are 4 different types of lhd heat sensor cables depending on the alarm temperature chosen.
Overview fyreline linear heat detection provides early warning of fire or overheating equipment.
The two cores are separated by a polymer plastic that is designed to melt at a specific temperature commonly 68 c for building applications and without which causes the two cores to short.
I have been a protectowire distributor for 25 years.
Out of kenilworth new jersey installed a fiber optic linear heat detection system for railroad platform protection in north america s busiest train station five years ago.
Linear heat detection is highly cost effective and can be easily installed with or in place of conventional heat detectors where traditional style.